Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
ImplantNews ; 11(1): 36-39, 2014. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-730048

ABSTRACT

A superfície dos implantes dentais é um fator determinante para o sucesso da osseointegra­ção, sendo caracterizada principalmente por parâmetros de rugosidade. Objetivos: caracterizar a topografia da superfície do implante Titaoss. Material e métodos: cinco implantes Titaoss com plataforma de hexágono externo e diâmetro 4,1 mm e 13 mm de com­primento de diferentes lotes foram analisados por microscopia eletrônica de varredura (MEV) e interferometria, para avaliação da morfologia e rugosidade da superfície. Resultados: as imagens de MEV demonstraram uma alta frequência de pequenas estruturas, que são características do tratamento de duplo ataque ácido. A quantificação numérica da rugosidade demonstrou uma altura média das estruturas (Sa) de 0,55 ± 0,16 μm com um incremento da área de superfície (Sdr) de 15,14 ± 3,78% e concentração de picos (Sds) de 0,102 ± 0,010/μm2. Conclusão: a superfície do implante Titaoss apresenta microestruturas decorrentes do tratamento com duplo ataque ácido compatíveis com outros sistemas de implantes já consolidados no mercado internacional. Estudos posteriores são necessários para comprovação clínica longitudinal do sistema.


The surface of dental implants, which is characterized by roughness parameters, is a key factor to determine the success of osseointegration. Objectives: to characterize the surface topography of Titaoss dental implant. Material and methods: five implants with external hexagon connection in 4.1 mm diameter platform and length of 13 mm from different batches were evaluated by scanning electron microscopy (SEM) and by interferometry to identify the surface morphology and quantify roughness. Results: SEM images exhibited high frequency of short structures, which are common in dual acid-etched surfaces. The numerical analysis of roughness reported a mean height deviation of the structures (Sa) of 0.55 ± 0.16 μm and an increase of surface area (Sdr) of 15.14 ± 3.78% with summit concentration (Sds) of 0.102 ± 0.010/μm2. Conclusion: the Titaoss implant presented surface microstructures due to dual acid treatment compatible with other implants already established in the international market. Further studies are necessary to ensure the long-term clinical success of this new implant system


Subject(s)
Dental Implants , Biocompatible Materials/analysis , Microscopy, Electron, Scanning
2.
Rev. odonto ciênc ; 26(1): 35-39, 2011. graf, tab
Article in English | LILACS, BBO | ID: lil-588599

ABSTRACT

PURPOSE: The objective of this study was to evaluate the effect of different immersion times in denture cleansers on surface roughness (SR) of two resilient denture liners (RDL) after the cleanliness of Candida albicans biofilm. METHODS: Poly(methyl methacrylate) (PMMA) resin discs (10x1.5 mm) were relined with a 1.5 mm layer of RDL (PMMA or silicone-based). The initial SR of each specimen was measured and C. albicans biofilm was developed for 48 h. Subsequently, the discs were randomly assigned for one of four cleansing treatments (n=8): two alkaline peroxide (soaking for 3 or 15 min), 0.5 percent sodium hypochlorite (10 min) or distilled water as control (15 min). After the treatments, the SR was measured again. Data were analyzed by ANOVA and the Tukey post-hoc test (α=0.05) RESULTS: No differences were found between the cleansing treatments evaluated (P>0.05). The PMMA-based liner exhibited higher SR than silicon-based (P<0.001); however, both liners showed higher SR after the reatments compared with the baseline values (P<0.001). CONCLUSION: Within limitations of this study, it can be concluded that the surface roughness of RDL increased after the immersion in denture cleansers, independently of the time of immersion.


OBJETIVO: O objetivo deste estudo foi avaliar o efeito de diferentes tempos de imersão em limpadores químicos sobre a rugosidade de superfície ( RS)de reembasadores resilientes após a simulação da limpeza de biofilmes de Candida albicans. METODOLOGIA: Discos (10x1,5 mm) de poli(metilmetacrilato) (PMMA) foram cobertos com uma camada de 1,5 mm de reembasador resiliente (a base de PMMA ou silicone). A RS inicial de cada espécime foi mensurada e biofilmes de C. albicans desenvolvidos por 48 h. Em seguida, os espécimes foram submetidos aleatoriamente a um dos tratamentos (n=8): duas soluções alcalinas a base de peróxido (imersão por 3 ou 15 min), hipoclorito de sódio a 0.5 por cento (10 min) ou água destilada como grupo controle (15 min). Após o tratamento, a RS foi mensurada novamente. Os resultados foram analisados por ANOVA e teste Tukey (α=0,05). RESULTADOS: Não houve diferença estatística entre os tratamentos (P>0,05). O reembasador a base de PMMA apresentou maior RS que os de silicone (P<0,001); entretanto, ambos apresentaram um aumento da RS após os tratamentos (P<0,001). CONCLUSÃO: Dentro das limitações deste estudo, conclui-se que a RS dos reembasadores resilientes aumenta após a imersão em limpadores químicos, independentemente do tempo de imersão.


Subject(s)
Disinfection , Denture Cleansers/adverse effects , Denture Liners , Surface Properties
SELECTION OF CITATIONS
SEARCH DETAIL